<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>7005</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: operation timed out
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
A "worst case" time to complete is calculated for all carriage move operations.  If the
move operation is not completed by this time, the "operation timed out" error is reported.
The maximum time allowed to move is:
</text></DescriptionText>
<DescriptionText><text>
timeout = 1.5 * distance to move / carriage speed
</text></DescriptionText>
<DescriptionText><text>
If this error is reported when performing a "carriage home" or "carriage away" (i.e.
retrace during normal operation), most likely the HOME/AWAY (HA) hardware failed
or the carriage has stalled.  In the case of a HA hardware failure, the carriage will be
jammed at either the home or away mechanical limit.  The alignment of the
HOME/AWAY board should be checked along with the cable.  If these appear ok, the
HOME/AWAY board should be replaced and re-aligned.  Note that if it is jammed at one
of the mechanical limits, the carriage will have to be moved past the HOME or AWAY
switch by manually turning the leadscrew.
</text></DescriptionText>
<DescriptionText><text>
If the carriage is stalling before reaching the mechanical limits, the tightness of the
leadscrew nut setscrew should be checked.  The leadscrew motor and belt should also be
checked.  The ALE can be swapped, as can the carriage drive board (Trendsetter only).
</text></DescriptionText>
<DescriptionText><text>
If this error is reported when performing a "carriage moveto &lt;position&gt; &lt;speed&gt;"
command, there are 2 known firmware problems that may be the cause:
</text></DescriptionText>
<DescriptionText><text>
1) In versions prior to 2.0,  the timeout was calculated using the default maximum speed
instead of the specified speed.  The only workaround is to use a speed greater than 2/3's
the default speed.
</text></DescriptionText>
<DescriptionText><text>
2) If it takes the carriage longer than 27 minutes to reach its target at the chosen speed,
this error will be reported.  For example, a speed of 10 mil/sec is chosen to move 17
inches.
</text></DescriptionText>
<DescriptionText><text>
If none of the above conditions apply, the error may be due to a failure of the carriage
controller on the ALE.  The ALE should be replaced.  If this does not fix the error, the
responsible firmware programmer should be contacted.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The platesetter may recover if "RESUME" or "CANCEL" are chosen. In any case, record
the error message and call Creo Service for help as the machine probably needs
servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Firmware bug in versions prior to 2.0? when speed is not maximum
</Cause>
<Cause>
HOME /AWAY board or cable is not working or misaligned
</Cause>
<Cause>
Carriage stalling due to excessive speed parameter
</Cause>
<Cause>
Carriage stalling due to electrical (motor, driver) or mechanical (belt, leadscrew nut)
problem
</Cause>
<Cause>
Unlikely failure of the carriage controller on the ALE
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:28 2008 PST
</Updated>
<Links>
</Links>
</Error>